Natural-gas combined-cycle plant
Combustion gas-turbine plant (topping-cycle)Steam Rankine plant (bottoming-cycle)
A topping gas turbine delivers electrical work and hands its exhaust enthalpy through heat-recovery steam generators to a bottoming steam Rankine cycle that delivers more; the two generators' outputs add. The combined cycle's efficiency belongs here and to neither member — 46.93 % at the Omani plant Al Mhanna et al. 2024 model — while each member keeps its own linear route and checks.
- what a system is
- Two or more linear pathways, each keeping its own route and checks, joined by a documented residual stream. The eight physics checks are not run over the system; it is not clear merely because its members are — every handoff must also be demonstrated.
- handoffs
- 1 recorded · weakest status demonstrated
- members' core checks
- Combustion gas-turbine plant: 1 core check unresolved · Steam Rankine plant: 1 core check unresolved — unresolved describes the atlas's evidence coverage of a member route, never a doubt about a plant that runs.
- knowledge level
- K8 · commercial technology
Members and their routes' checks
- 1TYPED ✓ENERGY ✓AVAILABILITY ✓THERMO BOUND ?DIMENSIONAL —BOUNDARY ✓REGIME ✓COVERAGE ✓· 1 core unresolved
- 2TYPED ✓ENERGY ✓AVAILABILITY ✓THERMO BOUND ?DIMENSIONAL —BOUNDARY ✓REGIME ✓COVERAGE ✓· 1 core unresolved
Handoffs between members
- 1Combustion gas-turbine plant → Steam Rankine plantrecovered heatdemonstratedthermal energy leaves the first member as Hot gas and establishes Temperature gradient, the disequilibrium the second member's route starts from.
- gas-turbine exhaust transfers residual enthalpy through a heat-recovery steam generator to establish the bottoming steam-cycle hot-side temperature relative to its condenser
Al Mhanna 2024's local plant: 540.7 °C gas-turbine exhaust into two-pressure heat-recovery steam generators (HP 235,400 kg/h and LP 40,000 kg/h feed; HP superheater exhaust 471.48 °C), the steam turbine delivering 61.5 MWrefs [1]
Outputs
- topping-cycle
- Electrical work · adds into the system output
- bottoming-cycle
- Electrical work · adds into the system output
Measured or reported performance of the system
- combined-cycle thermal efficiency46.93%plant2024basis: net gas-turbine plus steam-turbine power divided by natural-gas LHV inputlocal plant baseline (a 678 MW combined-cycle station in Oman, one gas-turbine train); natural gas 9.2 kg/s at LHV 43,662 kJ/kg; gas turbine ≈ 127 MW, steam turbine ≈ 61.5 MW; gas-turbine inlet 1050 °C, exhaust 540.7 °C — the plant's own figure (Table 3, local plant data); (127 + 61.5) MW over 9.2 kg/s × 43,662 kJ/kg = 401.7 MW reproduces it exactly — a verification, not a second measurement; the paper's Aspen Plus simulation gives 46.28 %refs [1]
Sources
- [1]N. M. Al Mhanna, I. Al Hadidi, S. Al Maskari. Simulation and Energy Analysis of Integrated Solar Combined Cycle Systems (ISCCS) Using Aspen Plus (2024)
- [2]A. Bejan. Advanced Engineering Thermodynamics (4th ed.) (2016)