Incident radiation flux → Electrical work
Incident radiation fluxPhotothermal absorptionTemperature gradientMarangoni effectFluid flowStreaming potentialIonic currentElectrical work
Epistemic state of the route
- known constituent relations
- 6 / 7 established or replicated · weakest constituent demonstrated
- constituent maturity floor
- K4 · experimentally observed
- search for this exact route
- Not assessed — complete composition not searched.
- recorded-pathway overlap
- shares relations, in order, with Concentrating solar-thermal plant · 2/7 relations shared
- route-level evidence
- 0 sources for the complete composition · 10 cited by the constituent steps
- boundaries and interfaces
- BOUNDARY compatible · no region transition
Explorematrix context · physics checks · steps · route evidence · constituent evidence · cite
Matrix context
D = disequilibrium row · C = coupling family column. A cell reads the state of the atlas for that pair.
D.11 × C.20 · Incident radiation flux × Photothermalfamily: PhotothermalD.11 × C.34 · Incident radiation flux × Marangonifamily: MarangoniD.11 × C.23 · Incident radiation flux × Electrokineticfamily: Electrokinetic
Typed bounds on this route
Every limit the atlas holds for this route, as constraint records: reached through bounded_by claims on the route's own entities. Hard bounds (an upper bound or a formula) decide the thermodynamic-bound check above; benchmarks, constitutive relations and resource limits are listed and never decisive. No prose limit exists anywhere (pass 42).
- Landsberg limit · formula-bound · hard, applies to this routeη ≤ 1 − (4/3)(T_c/T_s) + (1/3)(T_c/T_s)⁴ for conversion of blackbody radiation at T_s with a sink at T_c; 93.3 % at 6000 K / 300 K
- Carnot limit · formula-bound · hard, applies to this routeη ≤ 1 − T_c/T_h for any heat engine between reservoirs at T_h and T_c
- Onsager–Casimir reciprocity · constitutive-relation · listed, never decisiveL_ij(B) = ε_i ε_j L_ji(−B): the cross-coefficients of coupled linear transport are equal up to the time-reversal parities ε of the variables and reversal of the magnetic field; L_ij = L_ji is the zero-field, even-parity case
Steps
- 01radiative → thermal
- an absorber with high solar absorptance; selective surfaces suppress re-emission
illumination requiredrefs [1] [2] - 02thermal → thermalrefs [1]
- 03thermal → kinetic · loss to thermal
- thermocapillary case: surface tension falls with temperature, so a temperature gradient along the interface drives flow toward the cold side
liquid · temperature gradient requiredrefs [3] [4] - 04kinetic → kinetic · loss to thermal
- thermocapillary pumping of a liquid plug or droplet confined in a microchannel; the surface-tension gradient translates the plug rather than producing only local interfacial circulation
Thermocapillary pumping (TCP) of a discrete droplet in a closed microchannel: the plug's displacement and velocity were measured on the PZT device of Odukoya & Naterer 2013 and in their 2010 experiments. The confined translating plug is bulk, loadable flow; that fact must not leak onto open-surface Marangoni circulation, which keeps its own claim and tokens.refs [5] [6] - 05kinetic → electrical · loss to thermal
- the produced liquid flow passes a charged surface or through a charged channel; the charged boundary is a condition of the step
- not something the upstream flow provides
aqueous medium required · bulk flow required · charged surface requiredrefs [7] [8] - 06electrical → electricalrefs [8] [9]
- 07electrical → electrical · loss to thermal
- electrodes exchange the ionic current for an electronic current through the external load
refs [10]
Evidence for the complete composition · 0
No source on record for this exact composition. The sources below support the individual steps, not the route as a whole.
Evidence for the constituent relations · 10
- [1]A. Bejan. Advanced Engineering Thermodynamics (4th ed.) (2016)
- [2]P. T. Landsberg, G. Tonge. Thermodynamic energy conversion efficiencies (1980)
- [3]L. E. Scriven, C. V. Sternling. The Marangoni Effects (1960)
- [4]Q. Dai et al.. Directional interfacial motion of liquids: Fundamentals, evaluations, and manipulation strategies (2021)
- [5]P. S. Glockner, G. F. Naterer. Surface tension and frictional resistance of thermocapillary pumping in a closed microchannel (2006)
- [6]A. Odukoya, G. F. Naterer. Transient response of thermocapillary pumping of a droplet in a micro heat engine (2013)
- [7]J. Yin, et al.. Generating electricity by moving a droplet of ionic liquid along graphene (2014)
- [8]J. Yang et al.. Electrokinetic microchannel battery by means of electrokinetic and microfluidic phenomena (2003)
- [9]R. J. Hunter. Zeta Potential in Colloid Science: Principles and Applications (1981)
- [10]A. J. Bard, L. R. Faulkner. Electrochemical Methods: Fundamentals and Applications (2nd ed.) (2001)
Cite this route
Physical Transformation Atlas (2026). route p-2ae40d5536: Incident radiation flux → Photothermal absorption → Temperature gradient → Marangoni effect → Fluid flow → Streaming potential → Ionic current → Electrical work. Dataset revision rbfbfcbb70e57 (hash of the canonical data). https://physical-transformation-atlas.wldud5192.workers.dev/path/2ae40d5536
Ids and matrix addresses are stable across revisions; the revision hash identifies the exact canonical files the record was compiled from and is meta.data_hash in every /api export. Reuse terms: see the license field in any export.